AGM battery
Go Power

100 AH AGM Battery

$299.00

 

Features:

• AGM deep cycle battery

• Ideal for solar applications and

inverter systems

• Maintenance-free, sealed construction

• Spill proof / leak proof (VRLA)

• ABS case and cover

• UL recognized

• 100% recyclable

• Integrated carrying handles

SPECIFICATIONS

Technology AGM, VRLA deep cycle battery

Nominal Voltage 12 V

Nominal Capacity 110 Ah

Rated Capacity

Nominal Operating

Temperature

Operating

Temperature Range

Capacity Correction

for Temperature

Variations

Maximum Discharge

Current 1200 A (5s)

Internal Resistance Approx. 4.9mΩ

Terminals T14

Cycle Use

Standby Use

Certifications UL; CE; IEC60896-21 & 22

Self Discharge

Cycle Life

110.0 Ah/1.10A (100hr,1.80V/cell)

100.0 Ah/5.00A (20hr,1.80V/cell)

95.2 Ah/9.52A (10hr,1.80V/cell)

83.0 Ah/16.6A (5hr,1.75V/cell)

77 ±5 °F (25 ±3 °C)

Discharge, Storage: -4~140°F (-20~60°C)

Charge: -4~122°F (-20~50°C)

104°F (40°C) 103%

77°F (25°C) 100%

32°F (0°C) 86%

Torque: 11 ~ 14.7 Nm (97.28 - 130 in*lbs)

Initial Charging Current less than 30.0 A

Voltage: 14.4 V~15.0 V at 77°F (25°C)

Temp. Coefficient -30mV/°C

No limit on Initial Charging Current

Voltage: 13.5 V~13.8 V at 77°F (25°C)

Temp. Coefficient -20mV/°C

Batteries can be stored for up to 6 months

before a freshening charge is required.

*Batteries stored at temperatures greater than

77°F (25°C) will require a recharge sooner.

100% Depth of Discharge ~ 250 cycles

50% Depth of Discharge ~ 1100 cycles

30% Depth of Discharge ~ 2250 cycles

 

MATERIALS

Case and Cover ABS

Separator Absorbent Glass Mat (AGM)

Active PbO2 + Pb

Electrolyte Diluted Sulfuric Acid

Venting Valve Rubber, opening pressure 8-20kPa

MECHANICAL

Length 12.01 in / 305mm

Width 6.61 in / 168 mm

Height 8.15 in / 207 mm

Total Height

(including terminals) 9.02 in / 229 mm

BCI Group # 27

Weight 67.5 lbs / 30.6 kg

Carrying Integrated flush mount handles

Full Description

 

Features:

• AGM deep cycle battery

• Ideal for solar applications and

inverter systems

• Maintenance-free, sealed construction

• Spill proof / leak proof (VRLA)

• ABS case and cover

• UL recognized

• 100% recyclable

• Integrated carrying handles

SPECIFICATIONS

Technology AGM, VRLA deep cycle battery

Nominal Voltage 12 V

Nominal Capacity 110 Ah

Rated Capacity

Nominal Operating

Temperature

Operating

Temperature Range

Capacity Correction

for Temperature

Variations

Maximum Discharge

Current 1200 A (5s)

Internal Resistance Approx. 4.9mΩ

Terminals T14

Cycle Use

Standby Use

Certifications UL; CE; IEC60896-21 & 22

Self Discharge

Cycle Life

110.0 Ah/1.10A (100hr,1.80V/cell)

100.0 Ah/5.00A (20hr,1.80V/cell)

95.2 Ah/9.52A (10hr,1.80V/cell)

83.0 Ah/16.6A (5hr,1.75V/cell)

77 ±5 °F (25 ±3 °C)

Discharge, Storage: -4~140°F (-20~60°C)

Charge: -4~122°F (-20~50°C)

104°F (40°C) 103%

77°F (25°C) 100%

32°F (0°C) 86%

Torque: 11 ~ 14.7 Nm (97.28 - 130 in*lbs)

Initial Charging Current less than 30.0 A

Voltage: 14.4 V~15.0 V at 77°F (25°C)

Temp. Coefficient -30mV/°C

No limit on Initial Charging Current

Voltage: 13.5 V~13.8 V at 77°F (25°C)

Temp. Coefficient -20mV/°C

Batteries can be stored for up to 6 months

before a freshening charge is required.

*Batteries stored at temperatures greater than

77°F (25°C) will require a recharge sooner.

100% Depth of Discharge ~ 250 cycles

50% Depth of Discharge ~ 1100 cycles

30% Depth of Discharge ~ 2250 cycles

 

MATERIALS

Case and Cover ABS

Separator Absorbent Glass Mat (AGM)

Active PbO2 + Pb

Electrolyte Diluted Sulfuric Acid

Venting Valve Rubber, opening pressure 8-20kPa

MECHANICAL

Length 12.01 in / 305mm

Width 6.61 in / 168 mm

Height 8.15 in / 207 mm

Total Height

(including terminals) 9.02 in / 229 mm

BCI Group # 27

Weight 67.5 lbs / 30.6 kg

Carrying Integrated flush mount handles

Current Stock:
Shipping Cost: Calculated at Checkout
Width: 20.00
Height: 20.00
Depth: 20.00